Request Quotation

Details

Lutron PO2-250 DO Meter looks like a pen, it is very easy to use, easy to carry and measures the oxygen with acuracy.

Features:

  • Galvanic cell type for O2 sensor.
  • High reliability Oxygen sensor, not be affected by acidic gases like CO2.
  • Oxygen sensor with temperature compensated.
  •  Data hold, to freeze the desired reading value.
  •  Auto power off saves battery life.

FEATURES
 
* O2 ( Air oxygen ) and Temp. ( Air Temp. ) measurement.
* O2 measurement range : 0 to 30.0 % x 0.1 %.
* Temp. measurement range : 0 to 50 ℃, ℃/℉.
* O2 Buzzer warning : If the measurement value %O2, the buzzer will sound  for warning.
* Galvanic cell type for O2 sensor.
* High reliability Oxygen sensor, not be affected by acidic gases like CO2.
* Oxygen sensor with temperature compensated.
* Data hold, to freeze the desired reading value.
* Auto power off saves battery life.
* Operates from DC 1.5V ( UM4/AAA ) x 4 PCs batteries.
* Microprocessor circuit ensure high accuracy, and also and also provides special functions and features.
* Durable and compact ABS-plastic housing.
* Application : O2 monitor/dectors, Food  industrial ( Refrigerator, Vegetable factory ), Bio-Technology ( Oxygen incubator, Anaerobic cultivator ), Security system ( Air conditioner and Oxygen shortage alarm system, Fire alarm system ),  Fuel cell system.

 

GENERAL SPECIFICATIONS
Display LCD size : 28 mm x 19 mm.
Measurement O2 ( Air oxygen )
Temperature ( Air Temp. )
 
Sensor Oxygen Galvanic cell type
  Temperature Thermistor
Circuit Custom one-chip of microprocessor LSI Circuit
Data Hold Freeze the display reading.
Sampling Time Approx. 1 second.
Power off Auto shut off saves battery life.
Operating Temperature 0 to 50 ℃.
Operating Humidity Less than 80% R.H.
Power Supply DC 1.5 V battery ( UM4/AAA ) x 4 PCs.
Power Current Approx. DC 4.0 mA
Weight 194 g/ 0.43 LB.
Dimension 180 x 40 x 40 mm (7.1" x 1.6" x 1.6")
Accessories
Included
Instruction manual            1 PC
Soft carrying case ( CA-52A )   1 PC
Application * O2 monitor/dectors.
* Food  industrial : Refrigerator, Vegetable factory
* Bio-Technology : Oxygen incubator, Anaerobic cultivator
* Security system : Air conditioner and Oxygen shortage alarm system, Fire alarm system
* Fuel cell system.

 

ELECTRICAL SPECIFICATIONS  (23± 5 ℃)
O2 ( Air oxygen )
Range 0 to 30 %O2.
Resolution 0.1 %O2.
Accuracy ± ( 1 % reading + 0.2 % O2 ). @ After calibration
Response time ≦ 15 seconds.         @ t 90
Overload protection 100 %O2.
Environment pressure range 0.9 to 1.1 atmosphere.
Expected life time ≧2 years.
Alarm If the measurement Air oxygen value < 18.0 %O2, the buzzer wll sound for warning.

 

Temperature ( Air Temp. )
Range 0 ℃ to 50 ℃,32 ℉ to 122 ℉.
Resolution 0.1 degree
Accuracy ℃ - ± 0.8 ℃.
℉ - ±  1.5 ℉.

* Appearance and specifications listed in this brochure are subject to change without notice.

Data sheet

Manufacturer
LUTRON
Range
Oxygen: 0 to 30 %vol ; Temp: 0 to 50°C ,32°F to 122°F
Accuracy
O2: ± ( 1 % reading + 0.2 % O2 ) ; Temp: +/-0.8 ℃ , ± 1.5 ℉
Resolution
For Oxygen 0.1 % O2, For Temperature 0.1 degree
Measurement
O2 ( Air oxygen ),Temperature ( Air Temp. )
Display
LCD Display with size: 28 mm x 19 mm.
Sensors
Oxygen:Galvanic cell type,Temperature:Thermistor
Data Hold
Freeze the display reading.
Operating Range
For Temp:0 to 50 ℃, For Humidity:Less than 80% R.H
Sampling Time
Approx. 1 second
Power Supply
DC 1.5 V battery ( UM4/AAA ) x 4 PCs.
Dimensions
180 x 40 x 40 mm (7.1" x 1.6" x 1.6")
Weight
194 g/ 0.43 LB